11
Insufficient quantity of electricity
If there are too many collectors in your
proximity connected to the network at the
same time, the available voltage and the
current intensity may decline.
Consequently the motor of the high-pres-
sure cleaner does not start or even blows.
The power supply may also be insufficient
if the power cable is too long or too thin.
If extension cables are too long, this may lead to a voltage drop causing malfunctions or
start-up difficulties.
Check the line fusing and have the voltage and the available current
intensity checked by an expert in case of uncertainty.
Kränzle 1122 TST:
110 - 127 V ~, 14 A, 60 Hz
Electrical connection
The machine is supplied with a 5 meter electrical power cable with plug. The mains plug
must be fitted to a standard grounded socket with a 30mA residual current operated
device. The socket must be protected with a 16A delay action fuse on the mains side.
When using an extension cable, this must have an earthed lead which is properly
connected to the socket. The conductors in the extension cable must have a minimum
cross section of 1.5 mm².
Plug connections must be of a spray-proof design, and may not be located on a wet
floor. With extension cables of more than 10 m the minimum cross section must be
2.5 mm! When using a cable drum, always keep the cable wound as far as possible.